The difference between a composite flow double air inlet closed cooling tower and a composite flow single air inlet closed cooling tower

There are three cooling forms of closed cooling towers, namely composite flow closed cooling tower, counterflow closed cooling tower and cross flow closed cooling tower.

The composite flow closed cooling tower is divided into composite flow single inlet closed cooling tower and composite flow double inlet closed cooling tower. What are the differences between the two?

1、Design principles

First of all, from the design principle point of view, the working principle of the composite flow double-inlet closed cooling tower is based on the composite flow of wind and water. That is, two sets of air duct systems are set up inside the cooling tower, which are responsible for the air inlet and exhaust respectively. Cooling effect. The composite flow single-inlet closed cooling tower has only one air duct system, which is responsible for both air inlet and exhaust.

2 、cooling effect

Secondly, from the perspective of cooling effect, the composite flow double-inlet closed cooling tower can achieve better cooling effect because it has two sets of air duct systems. This is because the air intake and exhaust are carried out in a staggered manner, so that the hot air and the cooling medium are fully contacted, which enhances the heat transfer effect. Although the composite flow single-inlet closed cooling tower only has one air duct system, it can still achieve a certain cooling effect.

3、 floor space

Compared with the composite flow single-inlet closed cooling tower, the composite flow double-inlet closed cooling tower has a more complex structure and takes up more space. Because it requires two sets of air duct systems, the number of corresponding equipment and pipes will increase, and a larger site will be required to accommodate the cooling tower.

However, whether it is a composite flow double-inlet closed cooling tower or a composite flow single-inlet closed cooling tower, they have wide applicability in practical applications. They can effectively cool high-temperature fluids to ensure the normal production process. When choosing which type of cooling tower to use, comprehensive considerations need to be made based on specific process requirements and site conditions.

4 、Summary

In summary, there are differences in design principles, cooling effects, and floor space between composite-flow double-inlet closed cooling towers and composite-flow single-inlet closed cooling towers. But no matter what type of cooling tower, they are designed to meet the cooling needs in industrial production processes. In practical applications, the appropriate cooling tower type should be selected according to specific conditions to ensure efficient operation of production.